Medical equipment>Surgical emergency equipment>Sputum aspirator


1. SXT-5A Portable High Negative Pressure and High Flow Electric Sputum Aspirator for Smanfeng Sputum Ejector Household Sputum Ejector
2. SXT-1A Oil Free Vacuum Pump Portable Adult Sputum Ejector Portable Sputum Ejector
3. Simanfeng Sputum Aspirator YB-RX-1A Pediatric Type Non oil Pump Moderate Negative Pressure Pediatric Sputum Aspirator Household Pediatric Sputum Aspirator
4. The 7E-A portable electric sputum aspirator for fish jumping is small in size, light in weight, and easy to carry for adults
5. Conrad Electric Sputum Aspirator 9E-B
6. Jianghang Portable Sputum Aspirator ZH-H11
7. Lily sputum aspirator LE-2 handheld
8. Steel all manual sputum aspirator XT type
9. Fish Jump Pediatric Sputum Aspirator 7E-B Portable
Function of sputum aspirator:
The sputum aspirator is mainly used for routine suction, tracheotomy, and other treatments for patients. It is generally electric and is suitable for battlefield rescue suction in military companies, battalions, regiments, divisions, and other medical units, as well as suction in hospitals or any other medical unit without power supply.
The sputum aspirator has the characteristics of small size, light weight, high attractiveness, compact structure, easy portability, low cost, and durability.
Explanation of commonly used terms for electric suction devices:
Vacuum pump: a power device that generates negative pressure;
Collection container: a container for collecting liquid and solid particles;
Filter: a device for trapping particulate matter;
Intermediate piping: The pipeline between the collection container and the negative pressure source;
Overfill protection device: a device used to prevent liquid or solid particles from entering the intermediate pipeline;
Vacuum gauge: a device used to display the negative pressure value;
Vacuum regulator: a device used to control the magnitude of negative pressure for patients;
High negative pressure suction device: an suction device that produces a negative pressure value of no less than 60KPa;
High flow suction device: an suction device with an extraction rate of not less than 20L/min;
Low negative pressure suction device: an suction device that produces a negative pressure value not exceeding 20KPa;
Low flow suction device: an suction device with a suction rate less than 20L/min.
Daily maintenance of electric suction device:
1、 Daily maintenance of the suction device of the "oil immersed rotary vane pump" as a negative pressure source
When using, it is necessary to fully connect the filter and overflow protection device to prevent liquid and solid impurities from entering the pump body.
Regularly observe the oil level line, add oil in a timely manner, and avoid running the machine without oil.
Regularly change the oil. After using it for a period of time, water and other impurities will be sucked into the pump and mixed with oil, which can cause rust or accelerated wear of the pump body parts. Regularly replacing with new oil can not only reduce the failure rate of the machine, but also extend its service life.
Regular operation of the machine: During the shutdown period, it is recommended to operate the machine every two weeks for approximately 3-5 minutes to ensure its integrity.
2、 Daily maintenance of electric suction device with "oil free piston pump" as negative pressure source
When using, it is necessary to fully connect the filter and overflow protection device to prevent liquid and solid impurities from entering the pump body.
The continuous operation time should not be too long. After use, turn off the switch and disconnect the power supply in a timely manner.
3、 Shutdown processing
After the suction is completed, turn the regulating valve counterclockwise to the bottom to release the negative pressure in the pipeline. Wait until the negative pressure drops below 20KPa before shutting down.
After gastric lavage, the machine and pipelines should be rinsed, cleaned, and disinfected to avoid debris deposition and blockage of the pipelines.
The substances sucked out should be disposed of in accordance with medical waste disposal regulations
Used bottles and pipelines should be cleaned and disinfected according to the recommended method
The machine casing should be wiped with a damp cloth soaked in disinfectant water. Before wiping, it should be wrung dry to prevent water from seeping into the chassis
During the shutdown period of the machine, it should be stored in a ventilated and dry place and regularly checked for operation.

 